CKX31 - used to observe the standard cell culture, with fixed binocular microscope observation Combined with advanced UIS2 optical system, ensure the cell inspection and application of high definition CKX series microscope to check more quickly than the previous cell more convenient, simple operation, because they only need to adjust the optics, rarely spend few can get very good image. The tilting cylinder, users in the eyes observe can stand for observation. In addition, it is compact design with incubator, easy in observing some specimen user when do not need to go anywhere, very convenient. Support multiple observation, application scope is greatly increased. CKX series: make normal cells, observe easier and more efficient.
UIS2 optical system provides excellent optical properties UIS2 optical system combining the compact and light up like a lens of excellent performance, can remain an image of the image intensity, achieve superior optical correction level. Based on this point, UIS2 infinity correction optical system can provide special image resolution and contrast. Besides, the quality of image promotion F.N. can achieve maximum number of field. This makes CKX41 can use is observed microscope. (patent, only CKX41 have) High-resolution users easier to observe state of living cells Due to the combination of global fame UIS2 Olympus CKX series microscope optical system, improve the flat field for 10-15%, and can let hd, high contrast images of the extended until the image edge effect. Using UIS2 differ ring board, optimize the cell culture observation, provides the best image contrast UIS2 differ according to cultivate cells can link plate thickness adjustment contrast, provide better than the traditional system of image contrast. Objective to the greatest extent PHC can avoid vessel caused by the edge of the surface tension CPLN10 (PH, CPLFLN10 x x x PH) LCACHN20 PH, Objective to the greatest extent PHC can avoid shadows medium surface tension and the interference to interference, usually lower edge image resolution. Container Combining UIS2 optical system, flat field has been greatly improved, and even the observation on the edge of the vessel cells also can get very clear images. UIS2 infinity correction optical systems The revolutionary UIS2 Olympus optical system to infinity the advantage to get incisively and vividly. UIS2 infinity of light through the calibration of light will be formed after the objective parallel beams, meet like lens through after a focus in the middle of the form is like. Therefore in the objective lens with built-in like the light path between various accessories, not inserted into additional amplification factor to affect, total magnification lens and does not need to join correction. Insert the configuration of the various accessories, UIS2 optical system can still provide most excellent image quality.
Excellent performance
Sample placed in carrying platform, without any optical observations can adjust, immediately Difference of pre-mixed, heart, quick, no skateboard as poor observation Use a heart of pre-mixed skateboard without changing ideas repeated in every heart. In addition, 10, 20 (40 x telescope observations are used when a ring board, board are replaced ring. CKX series are easier to observe and do not need to undertake optical adjustment, can greatly improve the efficiency of the routine inspection.
Heart, adjustable ring board are When the need of high resolution image, Olympus offers adjustable ring board of heart IX2 - SL, through its perfect centering device, the difference image. Compact design, concise, and save experiment of space Simple and compact design greatly saves experimental space, convenient installation incubator or laminar equipment, remove the samples can be quickly under the microscope after observing, provide cell check efficiency. All kinds of accessories Blood count plate and other miniature plate carrying platform specimens These goods for observation platform specimen clip 35mm blood count plate, plate and other glass flasks, miniature plate provides convenience to observe.
project |
CKX31 |
Optical systems |
UIS2 optical systems |
Focus |
Through the telescope on the turntable moves up and down adjustable coke (carrying platform height fixed). Equipped with focus knob, trimming coaxial coarse institutions, adjustable, torque knob of roller institutions. Total stroke quantity: from 1mm high surface than carrying platform of focus from 7mm upward and downward 2mm. Rough schedule for each tone 39.6 mm, fine-tuning travel every lap 0.2 mm, fine-tuning precision 2 microns |
Objective turntable |
4hole |
Observe tube |
Plane carrying platform |
250mm 160mm (long) x width) (, can install specimen fixture |
With the skin type petri dishes 35mm aperture. |
Mechanical carrying platform |
Available with lower right position (X, Y coaxial transmission knob to. |
Small machine, X = 120mm trip: 78mm Y. With three petri dishes, specimen with Joe. |
Carrying sets up long plate |
70 (long) x 180 (wide) mm |
Lighting system |
illuminant |
With 6V30W halogen lamp and lamp plug (U - LS30-3-2), and heat within ground-glass filters, lighting department can dismantle. |
Filter |
Disassembly type, can cartridge filter 11mm maximum thickness of 45mm diameter filter. |
Aperture aperture |
Handle type, available in 3-44mm range. |
Plug insertion |
Equipped with differ in slippery seatcover, inside slider stops orientated. |
The condenser |
With the disassembling can work long distance condenser (numerical aperture, working distance for 0.3 72mm for). |
Differ slider |
Differ with slider in three different slider. Robert pre-mixed heart-shaped phase contrast method using slider: 4 x, 10 x / 20 x / 40 x, an empty hole Adjustable heart-shaped, its method using slider: 4 x, 10 x x, a/empty hole (40 x one3-bit pre-mixed heart-shaped), Adjustable heart-shaped, in line with relief method slider: 10, 20 and 40 x x x |
Double eyepiece tube |
Fixed double cone tube, the eyepiece 45 ° obliquity, pupil from within 48-75mm adjusted cylinder with spiral face, right, adjustable dioptre. |
Vertical fluorescent lighting devices |
Lighting devices, with observation to convert slider (three conversion position: B, G stimulate stimulate, transmission or U inspire. Fluorescent lights: 50W mercury Fluorescent light brake Fluorescence view aperture Fluorescence stimulate block: 2 stimulate block (B and G), optional U (not UIS2 and compatibility, and the size of the beam splitter and UIS2) Color: 1 the filter |
The eyepiece |
10×(F.N.20) |
Power supply device |
Continuous adjustable light intensity, built-in voltage switch (100/120V, 220/240V), frequency for 50/60Hz. | |